Home > News > Content
Circuit Breaker Breaking Capacity, Easy To Operate
Oct 09, 2017

A circuit breaker is a switching device capable of closing, carrying and breaking current under normal circuit conditions and capable of engaging and driving current under abnormal circuit conditions (including short circuit conditions) for a specified period of time. Circuit Circuit Breaker can be used to distribute power, not frequently start the asynchronous motor, the power lines and motors to protect, when they have a serious overload or short circuit and undervoltage problems such as failure to automatically cut off the circuit, its function is equivalent to fuse switch And a combination of overheat relays and the like. And generally do not need to change the parts after breaking the fault current. At present, has been widely used.

Circuit Circuit Breaker generally by the contact system, arc system, operating mechanism, release, shell and other components. Circuit breaker according to its structure is divided into miniature circuit Circuit Breaker, molded case circuit Circuit Breaker and frame circuit Circuit Breaker.

Cut off and connected to the load circuit, and cut off the fault circuit to prevent accidents to ensure safe operation. The high-voltage circuit breaker to break 1500V, current 1500-2000A of the arc, these arc can be extended to 2m still continue to burn does not go out. So the arc is high voltage circuit breaker must solve the problem.

Low-voltage circuit Circuit Breaker, also known as automatic air switches, can be used to turn on and off the load circuit, can also be used to control the motor is not frequent start. It is equivalent to the knife switch, over-current relay, loss of stress relays, thermal relays and leakage protector and other electrical parts of the sum of all the functions of low-voltage distribution network is an important protection of electrical appliances.

Low-voltage circuit Circuit Breaker with a variety of protection functions (overload, short circuit, under voltage protection, etc.), adjustable action value, breaking capacity, easy operation, security, etc., so now widely used. Structure and working principle Low-voltage circuit breaker by the operating mechanism, contacts, protection devices (a variety of release), arc system and other components.

Low-voltage circuit breaker main contact is by manual operation or electric closing. When the main contact is closed, the free trip mechanism locks the main contact in the closing position. The coil of the overcurrent release and the thermal element of the thermal release are connected in series with the main circuit, and the coil of the undervoltage release and the power supply are connected in parallel. When the circuit occurs short circuit or serious overload, the over-current release of the armature pull, so that the free trip mechanism, the main contact disconnect the main circuit. When the circuit is overloaded, the thermal element of the thermal release heats the bimetallic sheet to bend and push the free trip mechanism. When the circuit is undervoltage, the armature of the undervoltage release is released. Also let the free trip mechanism action. Shunt release is used as a remote control, in normal operation, the coil is power, in the need for distance control, press the start button, the coil power, armature drive free trip mechanism, so that the main touch Point off.

Now there are electronic type, the use of the transformer to collect the size of each phase current, compared with the set value, when the current is abnormal when the microprocessor sends a signal, so that the electronic release device to drive the action.